calcWGPort
- calcWGPort(port, SimDir, f, varargin)
Full definition:
[port] = calcWGPort( port, SimDir, f, varargin)
Calculate voltages and currents, the propagation constant beta and the characteristic impedance ZL of the given waveguide port.
The port has to be created by e.g. AddWaveGuidePort().
input:
port: return value of e.g. AddWaveGuidePort()
SimDir: directory, where the simulation files are
f: frequency vector for DFT
variable input:
‘RefImpedance’: use a given reference impedance to calculate inc and ref voltages and currents default is given port or calculated line impedance
‘RefPlaneShift’: use a given reference plane shift from port beginning for a desired phase correction default is the measurement plane at the end of the port the plane shift has to be given in drawing units!
‘RefractiveIndex’: set a material refractive index
‘SwitchDirection’: 0/1, switch assumed direction of propagation
output:
output signals/values in time domain (TD):
port.ut.tot: total voltage (time-domain)
port.ut.time: voltage time vector
port.it.tot: total current (time-domain)
port.it.time: current time vector
output signals/values in frequency domain (FD):
port.f: the given frequency fector
port.uf.tot/inc/ref: total, incoming and reflected voltage
port.if.tot/inc/ref: total, incoming and reflected current
port.beta: propagation constant
port.ZL: characteristic line impedance
port.ZL_ref: used reference impedance
example:
port{1} = calcWGPort( port{1}, Sim_Path, f, 'RefImpedance', 50);
(C) 2013 Thorsten Liebig (thorsten.liebig@gmx.de)
See also AddWaveGuidePort, calcPort