InitFDTD

InitFDTD(varargin)

Full definition:

function FDTD = InitFDTD(varargin)

Initialize the FDTD data-structure.

optional field arguments for usage with openEMS:

  • NrTS: max. number of timesteps to simulate (e.g. default=1e9)

  • EndCriteria: end criteria, e.g. 1e-5, simulations stops if energy has decayed by this value (<1e-4 is recommended, default=1e-5)

  • MaxTime: max. real time in seconds to simulate

  • OverSampling: nyquist oversampling of time domain dumps

  • CoordSystem: choose coordinate system (0 Cartesian, 1 Cylindrical)

  • MultiGrid: define a cylindrical sub-grid radius

  • TimeStep: force to use a given timestep (dangerous!)

  • TimeStepFactor: reduce the timestep by a given factor (>0 to <=1)

  • TimeStepMethod: 1 or 3 chose timestep method (1=CFL, 3=Rennigs (default))

  • CellConstantMaterial: set to 1 to assume a material is constant inside a cell (material probing in cell center)

examples:

%default init with 1e9 max. timesteps and -50dB end-criteria
FDTD = InitFDTD();

%init with 1e6 max. timesteps and -60dB end-criteria
FDTD = InitFDTD('NrTS', 1e6, 'EndCriteria', 1e-6);

%cylindrical FDTD simulation
FDTD = InitFDTD('CoordSystem', 1);

See also InitCSX


author: Thorsten Liebig (c) 2010-2013